Heat pumps
Furnace & heating
Ductless mini splits
Carrier
Trane
GoodmanSeasonal tune-up and full diagnostic on your Carrier, Trane, or Goodman system - readings shown to you before any repair is proposed
Diagnosis first, numbers second - you approve the repair price before a single part goes in.
Get your free estimateGoodman Heat Pump Service: The San Antonio Owner’s Guide
Goodman heat pump service in San Antonio typically runs $150 – $650 installed, depending on which component failed and whether we’re repairing or replacing it. We stock Goodman-compatible parts on our trucks for the most common failures: capacitors, contactors, defrost control boards, thermistors, and fan motors. Most calls are same-day, and every job starts with a written price before we touch a single screw.

Here’s the usual way it goes. You notice the system is blowing air that isn’t quite cold, or the outdoor unit is making a sound like a coffee grinder, or the whole thing just stopped running sometime in the night while the San Antonio humidity kept climbing. You check the thermostat, maybe the breaker. Then you call us because a Goodman heat pump that worked fine in March should not be limping through June. What broke is almost always one of five or six specific parts, and almost all of them can be fixed in one visit.
One thing we want to get in writing before anything else: Brandt HVAC Co San Antonio is an independent service provider. We are not affiliated with Goodman Manufacturing, and we don’t represent ourselves as a factory service arm. We work on Goodman equipment every week, we know the part numbers by heart, and we stand behind our repairs on our own terms.
Which Goodman Models This Applies To
This guide covers the Goodman heat pump lines most common in San Antonio homes: the GSZ series (GSZ14, GSZ16) and the GPH/GPC packaged heat pump units, plus the newer GSZB and GSZH models with scroll compressors. If your unit was manufactured in the last 12 years, you’ll typically find the full model number on a data plate attached to the outdoor unit, usually near the service valves on the back corner where the refrigerant lines enter the cabinet.
Here’s the compatibility gotcha that trips up a lot of homeowners trying to order parts themselves: Goodman changed defrost board designs between the GSZ14’s early and late production runs, and the two boards are not interchangeable even when the units look identical from the outside. The board part number is printed on the board itself, not always on the data plate. We match by that board number, not by the model number alone, because a wrong board will fit the mounting holes and still leave your heat pump stuck in defrost during a San Antonio summer afternoon.
On OEM versus aftermarket: for run capacitors and contactors, quality aftermarket parts (AmRad, Mars, Packard) perform just as well as Goodman-branded components and often last longer. For control boards and thermistors, we use OEM or OEM-equivalent parts because the logic tolerances matter. We’ll tell you which is which and why, and we’ll show you the part before we install it. If we don’t have it on the truck, we can usually have it at your San Antonio home by the next morning.
Styles & brands we work with






Signs Your Goodman Heat Pump Service Is Failing
- The outdoor unit hums but the fan doesn’t spin. This is almost always a failed run capacitor, and it’s the single most common Goodman heat pump service call we run in San Antonio. The capacitor gives the fan motor its starting kick; when it dies, the motor just sits there and the compressor eventually trips on thermal overload.
- The system runs but blows lukewarm air on cool days. In Texas winters, this often points to a failed reversing valve or a stuck defrost sensor. The heat pump can’t switch between heating and cooling modes properly, so it’s pumping heat out of your house when it should be pulling it in.
- Ice builds up on the outdoor coil in mild weather. That’s the defrost control board or the thermistor failing to cycle the unit into defrost. In San Antonio humidity, a heat pump that can’t defrost will freeze itself solid in under an hour.
- The outdoor unit short-cycles (starts, stops, starts). A failing contactor or a weak capacitor will cause rapid cycling, which overheats the compressor. A bad run capacitor in an August heat wave has killed more Goodman compressors than any other single fault we see.
- The whole system is dead and the breaker isn’t tripped. That’s usually a contactor that welded itself open or a transformer that cooked. We test line voltage, control voltage, and the contactor coil with a meter before we touch anything else.
See the difference
Before
After
Before
After
Before
AfterReplacement Cost & What’s Included
Here’s real money for San Antonio, not a national average. A capacitor replacement runs $150 – $290 installed. A contactor replacement runs $160 – $310. A defrost control board runs $280 – $480 parts and labor. A thermistor swap runs $120 – $220. An outdoor fan motor replacement runs $380 – $650. If the compressor itself has failed, you’re looking at a different conversation, and we’ll walk you through repair versus replacement honestly.
| Part | Installed Price Range (San Antonio) |
|---|---|
| Run capacitor | $150 – $290 |
| Contactor | $160 – $310 |
| Defrost control board | $280 – $480 |
| Thermistor / defrost sensor | $120 – $220 |
| Outdoor fan motor | $380 – $650 |
Every price above includes the part, the labor, the diagnostic work, and our written repair guarantee. The guarantee covers the installed part and the workmanship for 365 days. If that same repair fails inside a year, we come back at no charge, no argument. That’s the 365-Day Done Right Promise, and it’s written on every invoice.
What drives the price? The specific Goodman part number, whether it’s OEM or equivalent, and how accessible the component is inside your unit. We quote the price before the work starts, in writing, and we don’t start until you’ve seen it and agreed to it. If we open it up and find a second problem, we stop, show you, and requote. No surprises on the bill.

DIY or Call Us?
There are a few things you can safely check before calling, and they’re worth doing because they occasionally solve the problem for free. Confirm the thermostat is set correctly and the batteries aren’t dead. Check the breaker in your main panel. Look at the outdoor unit: if it’s iced over, shut the system off and let it thaw while you call us. Don’t run it frozen. That’s about where DIY ends.
Here’s the honest safety line: a heat pump capacitor holds a charge even with power off, and it can knock you on your back if you touch the terminals. The contactor is carrying line voltage. The defrost board and thermistor need a meter and a wiring diagram. We never recommend opening the service panel on any heat pump unless you have HVAC training and the right test gear. Hospital bills cost more than a service call, and a miswired board can take out your compressor.
If you’re in San Antonio and your Goodman heat pump is down, call us at (361) 470-8872. Devin Marlowe will tell you straight what’s wrong, what it costs, and when we can have it running. The quote is free. Most calls are same-day.
FAQs
Plan on 5 to 8 years in this climate. San Antonio summers work capacitors hard because the unit runs constantly, and heat is the enemy of the dielectric material inside. If your capacitor is past year six and the unit is short-cycling or slow to start, it’s not a matter of if, it’s when. Call us at (361) 470-8872 and we’ll test it on the spot. Free estimate.
No. Defrost boards are not field-repairable; when the relay welds or the logic chip fails, the board gets replaced. Some companies will try to replace just the relay. We won’t, because a board that failed once from a welded relay is a board with heat stress elsewhere, and we’d rather put in a part we can guarantee for a year without worry. Call (361) 470-8872 and we’ll give you an exact price for your board before we order anything.
Most capacitor, contactor, and thermistor swaps take 45 minutes to an hour once we’re on site. A defrost board runs 60 to 90 minutes including testing. A fan motor replacement can take two hours because we check the blade pitch and balance it after install. If you call before noon, we can usually be there the same day in San Antonio.
We stock capacitors in the common microfarad ranges (35/5, 40/5, 45/5), single and double-pole contactors in the amp ratings Goodman uses across the GSZ and GPH lines, universal thermistors, and the most common defrost boards. If we don’t have your exact board number, our parts house in San Antonio typically has it same-day, and we’ll schedule your install for the moment it’s in hand. Call (361) 470-8872 and we’ll check stock immediately.
One more thing about the crew. Every technician we send to a San Antonio home is background-checked, identity-verified, and introduced to you by name and photo before they arrive. They’ll show a photo ID badge at the door. We built the company on that, because opening your door to a stranger is exactly what this should never feel like. Brandt comes from an old word for a firebrand, and we figure keeping a home warm and cool is a fitting job for the name. We also service Carrier, Trane, and Lennox, so if you’ve got an oddball mixed system, we can handle that too.
Tell me what’s wrong, I’ll tell you what it costs, and we’ll get your house back to livable.
Written by Devin Marlowe, Owner, Brandt HVAC Co San Antonio at Brandt HVAC Co San Antonio, serving San Antonio and nearby areas.